The TRONICAM20 electronic control unit can be built into a three DIN module cabinet. It gives complete control of the boiler-flue (heat flue) using a temperature selection switch to start the heat pump, with a led signal when it is running. The exact temperature reading of the water is shown on the large display. If it overheats (approx. 95°C) a sound and visual alarm is triggered. The unit also has an independent switch for the rotisserie and is fitted with a probe-housing pocket. If required, the boiler-flue can be integrated with a traditional boiler through the TRONICAM20 unit , to produce hot running water and/or hot water for heating (refer to the diagrams on the back).

posta
   


1 Electronic unit
2 Temperature reading probe
3 Grill motor
4 Heat pump
5 Room thermostat
6 Three way solenoid


7 Radiator
8 Flue-boiler
9 Hot running water
10 Heating boiler
11 Running water boiler.